Ground Engineering Consultants, Inc.
Commerce City,
Colorado
View Accreditation Certificate
Evan
Kuhn
7393 Dahlia Street
Commerce City
,
Colorado
80022
Phone: (303) 895-3780
Fax:
evan.kuhn@groundeng.com
http://www.groundeng.com
Quality Management System - accredited since 3/15/1996 R18, C1077 (Aggregate), C1077 (Concrete), C1093 (Masonry), D3666 (Aggregate), D3666 (Asphalt Mixture), D3740 (Soil), E329 (Aggregate), E329 (Asphalt Mixture), E329 (Concrete), E329 (Masonry), E329 (Soil), E329 (Sprayed Fire-Resistive Material)
Asphalt Mixture - accredited since 3/15/1996 R30, R47, R68, R97, T30, T166, T209, T245, T269, T283, T287, T308, T312, T329, T331, T355, CP-L 5106, CP-L 5115, D979, D2041, D2726, D2950, D3203, D3549, D3665, D4125, D4867, D5444, D6307, D6752, D6925, D6926, D6927
Soil - accredited since 3/15/1996 R58, R74, T88, T89, T90, T99, T100, T134, T135, T136, T180, T190, T191, T193, T208, T215, T216, T236, T265, T288, T310, D421, D422, D558, D559, D560, D698, D854, D1140, D1556, D1557, D1883, D2166, D2216, D2434, D2435, D2487, D2488, D2844, D3080, D4318, D4546, D4643, D4718, D5084, D6913, D6938, G187
Aggregate - accredited since 3/15/1996 R76, R90, T11, T19, T21, T27, T84, T85, T96, T104, T112, T176, T255, T304, T327, T335, C29, C40, C88, C117, C127, C128, C131, C136, C142, C535, C566, C702, C1252, D75, D2419, D4791, D5821, D6928, D7428
Sprayed Fire-Resistive Material - accredited since 6/7/2012 E605, E736
Concrete - accredited since 3/15/1996 M201, R39, R60, R100 (Beams), R100 (Cylinders), R115, T22, T24 (Testing Drilled Cores of Concrete), T97, T119, T121, T148, T152, T160, T196, T231 (5000 psi and below), T303, T309, C31 (Beams), C31 (Cylinders), C39, C42 (Testing Drilled Cores of Concrete), C78, C138, C143, C157, C172, C173, C174, C192, C231, C305, C511, C617 (5000 psi and below), C642, C805, C1064, C1231 (7000 psi and below), C1260, C1567
Masonry - accredited since 11/18/2005 C140 (Concrete Masonry Units) (Sampling and Testing Concrete Masonry Units and Related Units) C511 (Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the testing of Hydraulic Cements and Concretes) C780 (Annex 1) (Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry - Consistency by Cone Penetration) C780 (Annex 4) (Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry - Mortar Aggregate Ratio) C780 (Annex 6 - Cubes) (Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry - Compressive Strength of Cubes) C780 (Annex 6 - Cylinders) (Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry - Compressive Strength of Cylinders) C1019 (Sampling and Testing Grout) C1314 (Compressive Strength of Masonry Prisms) C1552 (Capping Concrete Masonry Units, Related Units and Masonry Prisms for Compression Testing)
Please note that our accreditations do not include an expiration date. An accreditation only expires when the laboratory fails to comply with our accreditation requirements.
* This information is only valid as of 10/27/2026. Please visit https://aashtoresource.org for current accreditation status.
|